Input | |||||
Description | Min | Typ. | Max. | Units | Comment |
Voltage | 90 | 100~240 | 264 | Vac | |
Frequency | 47 | 50/60 | 63 | Hz | |
Description | Min | Typ. | Max. | Units | Comment |
Operating Temperature | 0 | - | 40 | ℃ | |
Storage Temperture | -20 | - | 65 | ℃ | |
Operating Humidity | 5 | - | 95 | %RH | |
Storage Humidity | 5 | - | 95 | %RH | |
output voltage | output current | precision | Ripple | Noise | Efficiency | No-Load |
5.0V | 1.5A | ±5% | 150mV | 150mV | 76.65% | 0.1W |
5.0V | 2.0A | ±5% | 150mV | 150mV | 78.70% | 0. 1W |
5.0V | 2.4A | ±5% | 150mV | 150mV | 79.94% | 0. 1W |
■ MeasurementCondition 1.Measurements shall be made with an oscilloscope with 20MHz bandwidth. 2.Outputs shall be bypassed at the connector with a 0.1μF ceramic disk capacitor and a 10μF electrolytic capacitor to simulate system loading. | ||||||